Rincian Produk
Tempat asal: Cina
Nama merek: Tankii
Sertifikasi: ISO9001
Nomor model: K
Ketentuan Pembayaran & Pengiriman
Kuantitas min Order: 5 ~ 10 kg per diameter
Harga: USD34~60/kg
Kemasan rincian: Pada bungkus spool dan karton.
Waktu pengiriman: 5-7 hari
Syarat-syarat pembayaran: T/T, Paypal, Western Union, MoneyGram,
Menyediakan kemampuan: 2000 ton per tahun
barang: |
TANKII Batang/Batang Termokopel Alumel Chromel 8.0mm |
Kemasan: |
dalam kumparan atau panjangnya |
Bahan: |
NiCr-NiAl |
Permukaan: |
cerah atau teroksidasi sesuai permintaan |
Diameter yang tersedia: |
0,05mm-12mm dapat diproduksi |
MOQ: |
5 ~ 10kg sesuai ukuran |
Pembayaran: |
TT, Paypal, Western Union, |
Waktu Pimpin: |
5 ~ 20 Hari |
barang: |
TANKII Batang/Batang Termokopel Alumel Chromel 8.0mm |
Kemasan: |
dalam kumparan atau panjangnya |
Bahan: |
NiCr-NiAl |
Permukaan: |
cerah atau teroksidasi sesuai permintaan |
Diameter yang tersedia: |
0,05mm-12mm dapat diproduksi |
MOQ: |
5 ~ 10kg sesuai ukuran |
Pembayaran: |
TT, Paypal, Western Union, |
Waktu Pimpin: |
5 ~ 20 Hari |
Thermocouple rods are processed through wire drawing, welding, assembly, insulation, and encapsulation to create various types of thermocouples, widely used in almost all industrial and scientific research applications requiring temperature measurement.
Types of thermocouples manufactured include:
1, Assembled thermocouples: The most common type, used for insertion temperature measurement in pipes, containers, and furnaces.
2, Sheathed thermocouples: These are formed by drawing the thermocouple wire, insulating material (such as magnesium oxide), and metal sheath into a single piece; they are thinner, more flexible, have a faster response, and are pressure and corrosion resistant.
3, Surface thermocouples: Used to measure the surface temperature of solids.
4, Consumable thermocouples: Used for instantaneous temperature measurement of molten metals such as molten steel and iron.
What differentiates one thermocouple from another is the metals in its two wires: the positive leg and the negative leg. Because each thermocouple type has a different pairing, they differ in temperature limits, process conditions (inert, oxidizing, reducing atmospheres, heavy vibration), and so on.
|
Conductor Name |
Thermocouple Type |
Grade |
Temperature range ℃ |
Allowable Tolerance /℃ |
| PtRh30-PtRh6 | B | Ⅱ | 600~1700 | ±0.25% t |
| Ⅲ | 600~800 | ±4 | ||
| 800~1700 | ±0.5%t | |||
| PtRh13-Pt | R | Ⅰ | 0~1100 | ±1 |
| 1100~1600 | ±[1+(t-1100) ×0.3%] | |||
| Ⅱ | 0~600 | ±1.5 | ||
| 600~1600 | ±0.25% t | |||
| PtRh10-Pt | S |
Ⅰ |
0~1100 | ±1 |
| 1100~1600 | ±[1+(t-1100) ×0.3%] | |||
|
Ⅱ |
0~600 | ±1.5 | ||
| 600~1600 | ±0.25% t | |||
| NiCr-Ni | K | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
| Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | ||
| Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | ||
| NiCrSi-NiSi | N | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
| Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | ||
| Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | ||
| NiCr-CuNi (Constantan) | E | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
| Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | ||
| Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | ||
| Fe-CuNi (Constantan) | J | Ⅰ | -40~750 | ±1.5℃ or ±0.4%t |
| Ⅱ | -40~750 | ±2.5℃ or ±0.75%t | ||
| Cu-CuNi (Constantan) | T | Ⅰ | -40~350 | ±0.5℃ or ±0.4%t |
| Ⅱ | -40~350 | ±1.0℃ or ±0.75%t | ||
| Ⅲ | -200~40 | ±1.0℃ or ±1.5%t |